Standard QQI's

Basic circular and crossed bar flaw configuration suitable for longitudinal and circular fields

CX-230 QQI

Similar to KSC-230 or 625551 (519630)

Standard QQI, flaw depth of 30% Shim thickness, 0.002″ thick

CX-430 QQI

Similar to KSC-430 or 625553 (521048)

Standard QQI, flaw depth of 30% Shim thickness, 0.004″ thick

Miniature QQI's

Similar to CX-230, except miniature design for small areas on test part. The four circles may be cut apart for individual use.

CM-230 QQI

Similar to KSC-4-230, 625552 (519631) or CX4-230 Miniature QQI with four circles per sheet, flaw depth 30% Shim thickness, 0.002″ thick

Variable Depth QQI's

These QQI’s are used for more quantitative work, three concentric circular flaws of differing depths.

3C2-234 QQI

Similar to KSC-2-234 or 625554 (519632)

Variable depth flaws of 20%, 30% and 40% of Shim thickness, 0.002″ thick

3C4-234 QQI

Similar to KSC-4-234 or 625555 (521049) Variable depth flaws of 20%, 30% and 40% of Shim thickness, 0.004″ thick